Shanghai Guanlong valve brand promotion ZBSF stainless steel flange valve DN15

Steam solenoid valve can be widely used in textile, printing, chemical, plastics, rubber, pharmaceutical, food, building materials, machinery, electrical appliances, surface treatment and other production and research sectors and bathroom, dining room, air conditioning and other facilities of daily life. ZBSF-Y series solenoid valve is mainly used for controlling the corrosive liquid, clean liquid and edible liquid liquid medium. ZBSF series solenoid valve is mainly used for corrosion control of gas, clean gas and other gaseous media.

price:USD$640.00
discount 70% in 2018-07-19 to 2018-07-21
price: USD$ 448.00
freight :USD$18.00,(Express)
freight :USD$7.00,(Postal parcel)
views:0
Search Similar or mail to saler or send message to saler

Pay with PayPal, PayPal Credit or any major credit card

The whole shop full cut Date: 2015-04-2210:13:53-2015-06-1110:13:53
Single orders over1000 elementreduce 50 element Free shipping (not including Hong Kong and Taiwan and overseas)

This product price does not include freight, freight on weight, unified written as 1KG, because the store is not the same size caliber product specifications can not calculate, buyers take product re calculated by the shop according to the location and weight of the product, according to the actual amount of, thank you.

The main sales:

  Gate valve, butterfly valve, (bellows) cut-off valve, ball valve, check valve, relief valve, safety valve, needle valve, discharge valve, breathing valve, flame arrester, mud valve, pneumatic angle seat valve, exhaust valve, filters, drain valve, valve, diaphragm valve, plunger valve, cock valve, hydraulic control valve, balance valve, drain valve, solenoid valve, mirror, copper valve, heat preservation valve, gas valves, bellows valves, plastic valves, lined valves, stainless steel valves, high pressure valves. Drive can be manual, pneumatic, electric, gear and other devices.

Suitable for: water, steam, oil, nitric acid, acetic acid; strong oxidizing medium: urea, oxygen, gas, ammonia, methanol, ethane, propane and other various media. Widely used in the field of electric power, power, light industry, textile, chemical industry, metallurgy, pharmaceutical, food, mining, construction, environmental protection, fire protection, air conditioning etc..

Because of too many types of products, the price is not the final transaction price, the need to please contact us. Special products need to customize..

Mobile phone: 13381801330

ZBSF stainless steel solenoid valve flange

purpose

ZBSF seriesAll stainless steel solenoid valveThe actuator is used in industrial process automation control system. It can automatically open or close in an electronic signal, the liquid medium in the pipeline off or flow control.

Steam solenoid valve can be widely used in textile, printing, chemical, plastics, rubber, pharmaceutical, food, building materials, machinery, electrical appliances, surface treatment and other production and research sectors and bathroom, dining room, air conditioning and other facilities of daily life. ZBSF-Y series solenoid valve is mainly used for controlling the corrosive liquid, clean liquid and edible liquid liquid medium. ZBSF series solenoid valve is mainly used for corrosion control of gas, clean gas and other gaseous media.

Steam solenoid valve model specifications

The main features of steam solenoid valve

Corrosion resistance of stainless steel or cast stainless steel: the vast majority of parts made of good corrosion resistance.

Heat seal: electromagnetic part, all the special high temperature electrical materials and sealing materials, and the use of effective insulation measures.

Wear: selection and reasonable guidance suite valve cup and clever use of fluid lubrication, reduce wear.

Reliable: has the advantages of simple and compact structure, integration of the direct drive type and indirect pilot solenoid valve, can work reliably in low or zero pressure condition.

Steam solenoid valve structure principle

The valve is a direct step pilot solenoid valve action, according to the on-off state of the different power failure, can be divided into normally closed solenoid valve and a normally open solenoid valve. Normally closed solenoid valve coil is energized, the armature of the electromagnetic force of the first drive valve and vice, and open the main valve pressure difference and the effect of electromagnetic force in the formation of the medium. Coil power, armature component reduction, the main and auxiliary valve using medium pressure and close off.

The normally open solenoid valve coil is energized, the magnetic effect of the armature down, push the Deputy valve plug and seat down, until the side pressing, the Deputy valve closed, the main valve valve cup under pressure tends to be equal, the main valve valve cup by magnetic and gravity pressing close the cover, the valve is closed. Coil power, the magnetic force is zero, the armature and the auxiliary valve plug by spring up, vice valve is opened, the main valve valve cup medium flow out by the vice valve, pressure drops, the main valve cup by pressure difference rises up, the main valve is opened, the valve opens.

Steam solenoid valve technology parameters

project

Explain

Working medium

Corrosive fluid, clean fluid, fluid consumption
ZBSF-1: ZBSF-1Y: liquid gas
ZBSF-2: ZBSF-1Y: liquid gas

The temperature of the medium (c)

ZBSF-1(1Y):≤60℃

ZBSF-2(2):≤280℃

Nominal pressure (MPa)

1.6

Working pressure (MPa)

0~1.6

0.05~1.6

Nominal diameter (mm)

10

15

20

25

32

40

50

65

80

100

125

150

supply voltage

The AC220V specification can be used for a special order

Service life

According to the provisions of JB/T7352-94

Rated flow coefficient

 

Leakage

According to the provisions of JB/T7352-94 - F

Power waste

AC≤70VA

Ex-mark

DIIBT4

Explosion proof certificate number

CE991010

Outlet connector

Thread M20 * 1.5

ambient temperature

-40~+60℃

Steam solenoid valve size

DN

L

H

D

D1

D2

b

f

n-d

10

115

148

Φ90

Φ60

Φ41

14

2

4-Φ14

15

115

148

Φ95

Φ65

Φ46

14

2

4-Φ14

20

115

148

Φ105

Φ75

Φ56

16

2

4-Φ14

25

125

148

Φ115

Φ85

Φ65

16

3

4-Φ14

32

150

182

Φ140

Φ100

Φ76

18

3

4-Φ18

40

165

182

Φ150

Φ110

Φ84

18

3

4-Φ18

50

190

192

Φ160

Φ125

Φ99

20

3

4-Φ18

65

290

265

Φ185

Φ145

Φ118

20

3

8-Φ18

80

310

276

Φ200

Φ160

Φ132

20

3

8-Φ18

100

350

373

Φ220

Φ185

Φ156

22

3

8-Φ18

125

400

416

Φ250

Φ210

Φ184

22

3

8-Φ18

150

480

440

Φ285

Φ240

Φ211

24

3

8-Φ22

Steam solenoid valve installation instructions

1, install the solenoid valve coil up and maintain the vertical position, solenoid valve on the arrow or marker should be consistent with the pipeline flow, shall not be installed in a splash of water or Water Leakage place.

The working medium 2, solenoid valve should be clean and free of particulate impurities, electromagnetic valve and surface dirt on the filter must be clean regularly.

3, solenoid valve failure, in order to prompt isolation valve, and ensure the normal operation of the system, the best install the bypass device (Figure 1). Note: the bypass valve on the usual must be closed. If the solenoid valve is installed on the bracket, the solenoid valve diameter should be less than the main pipeline valves. Figure (two).

4, before the installation of solenoid valves, piping must be clean. Recommended valve installed before the filter, steam pipe installed traps.

5, don't put the concave valve installed in the pipeline, so as to avoid condensation of water vapor, impurities deposited on the valve and prevents action.

6, ordinary type can not be used in explosive situations.

7, in the pipeline insufficient rigidity of the case, it is recommended that the valve before and after the pipe bracket, to prevent vibration caused by electromagnetic valve work.

8, before installation, see the product label, carefully read the instruction manual to determine whether the products meet the conditions of use.

After 9, the solenoid valve should be installed on the pipeline pressure gauge, in order to observe the pipeline pressure.

Steam solenoid valve maintenance

1, the proposed use of units assigned responsibility for maintenance.

2, solenoid valve installed, shall pass into the media try to confirm the normal action several times, shall be put into use.

3, the valve should be cleaned inside and outside and the armature is attracted and the dirt regularly. Be careful not to damage the sealing surface.

4, the electromagnetic valve is not used for a long time, should close the valve before the valve manually, re enabled when the steam solenoid valve should be condensed water removal clean, and try to switch the normal action several times, before being put into use.

No 5, solenoid valve from the pipeline should be removed, the internal parts of test net and blow out with compressed air storage.

6, used for a long time, such as the piston and the valve seat seal is not good, the piston sealing surface and the valve seat grinding and re grinding.

7, work, should pay attention to the valve and pressure gauge, working pressure shall not exceed the rated pressure, working pressure must be within the range of the rated pressure. When the working pressure exceeds the rated pressure or working pressure exceeds the rated pressure, solenoid valve to stop using, before and after the closure of the manual valve, solenoid valve to prevent leakage and explosion.

Steam solenoid valve ordering

1, please specify when orderingSteam solenoid valveModel、Steam solenoid valveNominal diameter,Steam solenoid valveNominal pressure,Steam solenoid valveWorking medium,Steam solenoid valveWorking pressure,Steam solenoid valveMedium temperature,Steam solenoid valveThe power supply voltage and power,Steam solenoid valveMedium viscosity.

2The voltage, the electromagnetic valve is in normal work for220

+22

V, if more than this range, indicating the fluctuation of voltage when ordering please. Other specifications of the power supply voltage can be a special order.

-15

3, the valve opening time of 12 hours / day or more, please use the normally open solenoid valve. When using the environment around the inflammable and explosive materials, please use the explosion-proof solenoid valve.