Menu

Connect with us

ZCZP-16C cast steel flange solenoid valve pipe, oil steam high temperature solenoid valve normally closed 8 inch DN200

price:USD$4955.00
discount 70% in 2018-07-23 to 2018-07-25
price: USD$ 3468.50
freight :USD$18.00,(Express)
freight :USD$7.00,(Postal parcel)
views:0
Search Similar or mail to saler or send message to saler

Pay with PayPal, PayPal Credit or any major credit card

bookvalveIt is a solenoid valve with pilot two opening valve made up of two main parts: auxiliary valve and main valve. It depends on the opening and closing of the auxiliary valve to control the on-off of the main valve. According to the switch state when the power switch is different, it can be divided into normally closed solenoid valve and normally open solenoid valve. Normally closed solenoid valve, the power of normal position, the auxiliary valve port is closed, the main valve is cut off, when the signal into the pilot valve coil, the movable iron core is driven by electromagnetic force vice valve open suction mouth, rapid disappearance of the main valve valve cup pressure, medium pressure to the main valve valve cup holder, open the main the valve port, hard working medium circulation. But when the electric signal disappears, the movable iron core is reset, closing the auxiliary valve port, and the working medium self balancing hole enters into the valve cup. When the pressure tends to balance, the valve cup is moved down by the main valve spring, the valve cup self weight and the medium pressure, and the main valve port is tightly sealed, and the valve is closed. Normally open solenoid valve, in the power off position, by the role of the spring, vice valve opening, the main valve circulation. When the signal into the auxiliary valve coil, the movable iron core electromagnetic suction effect, the auxiliary valve port is closed, the working medium by balancing hole into the valve cup, when the pressure tends to balance, on the main valve spring, valve cup self weight and the medium pressure valve sealing cup down, close the main valve port, the valve is closed state. When the main valve is powered off, the electromagnetic force disappears, the vice valve opens, the main valve cup pressure disappears rapidly, the medium pressure will be the main valve cup support, open the main valve port, medium circulation, the valve is open.

 

purpose

 

The valve applies to the steam as the heating medium, automatic temperature control of the implementation of the agency. The steam boiler, radiator, dryer and other steam equipment and all kinds of temperature control instrument, steam shaping machine, steam dye machine, steam resurgence machine and other complete sets of equipment steam boiler pipe two position automatic control and remote control area. Widely used in automatic control system of dyeing, textile, food, medicine, tobacco, cement, petrochemical, metallurgy and other departments.

 

main parameter

 

project

Explain

Working medium

Steam and other non corrosive gases

Medium temperature (c)

≤200

Nominal pressure (MPa)

1.6

Working pressure difference (MPa)

0.05~1.6

0.10~1.6

supply voltage

AC220VThe other specifications can be used for special orders

Service life (10000 times)

≥10

≥5

≥3

Nominal diameter (mm)

15

20

25

32

40

50

65

80

100

125

150

Rated flow coefficient (KV)

2.8

5

8.5

12

18

28

45

70

110

180

250

Leakage volume (ml/min)

1.5

3

4.5

6

9

17

28

40

Power waste

50VA

Ex-mark

DIIBT4

Explosion proof number

CE991010

Outlet joint

Internal thread M20 * 1.5

ambient temperature

-40~+60℃

 

 

Installation size

 

Nominal diameter DN

Internal thread connection

Flange connection

Outline size

Internal thread

Outline size

Flange size

H

L

G

H

L

D

D1

D2

b

f

n-d

15

148

92

1/2

176

130

65

65

46

14

2

4-Φ14

20

148

92

3/4

181

150

105

75

56

16

2

4-Φ14

25

148

110

1

210

160

115

85

65

16

3

4-Φ14

32

182

120

11/4

221

180

140

100

76

18

3

4-Φ18

40

182

140

11/2

230

200

150

110

84

18

3

4-Φ18

50

192

162

2

252

230

165

125

99

20

3

4-Φ18

65

 

 

 

265

290

185

145

118

20

3

4-Φ18

80

 

 

 

276

310

200

160

132

20

3

8-Φ18

100

 

 

 

373

350

220

180

156

22

3

8-Φ18

125

 

 

 

416

400

250

210

184

22

3

8-Φ18

150

 

 

 

440

480

285

240

211

24

3

8-Φ22

 

Installation instructions

 

1, install the solenoid valve coil up and maintain the vertical position, solenoid valve on the arrow or marker should be consistent with the pipeline flow, shall not be installed in a splash of water or Water Leakage place.

 

2. The working medium of the solenoid valve should be clean without particle impurities, and the dirt and filter on the inner surface of the solenoid valve should be cleaned regularly.

 

3, in the solenoid valve failure, in order to isolate the solenoid valve in time, and ensure the normal operation of the system, it is best to install bypass devices (Figure 1).

 

4, in the pipeline system, the solenoid valve installed on the branch should be smaller than the diameter of the main pipeline valve (Figure two).

 

5, before the installation of solenoid valve, the pipeline must be cleaned. It is recommended to install filter in front of valve and install drain valve in steam pipe.

 

6, can not be concave valve installed in the pipeline, so as to avoid condensation of water vapor, impurities deposited on the valve and prevent action.

 

7, ordinary type can not be used in explosive dangerous occasions.

 

8, in the case of lack of rigidity of the pipeline, it is recommended to fix the pipeline before the valve, so as to avoid the vibration caused by the solenoid valve working.

 

9, before installation, should pay attention to see the product signs, carefully read the instructions, to determine whether the product meets the conditions of use.

 

10, solenoid valve before and after the installation of pressure gauges on the pipeline, in order to observe the pipeline pressure.

 

 

 

Service and maintenance

 

1, it is recommended that the use of units to send special personnel responsible for the use of maintenance.

 

2, solenoid valve installed after the media to enter the experimental action several times, to confirm the normal rear can be formally put into use.

 

3, should regularly clean large valve inside and outside the suction surface, pay attention to do not damage the sealing surface.

 

4, when the solenoid valve is not used for a long time, the valve should be closed before the manual valve, when re opened, the steam solenoid valve should be condensed water clean, and try several times, pending the switch is normal, can be put into use.

 

5. When the solenoid valve is unloaded from the pipeline, the internal parts should be cleaned and stored in compressed air.

 

6, the use of a long time, such as the piston and valve seat seal is not good, the piston sealing surface can be re polished, and now the valve seat grinding.

 

7, the work should pay attention to the pressure gauge before and after the valve, requiring the work pressure shall not exceed the rated pressure, the work pressure difference must be within the rated pressure range. When the working pressure exceeds the rated pressure or the working pressure difference exceeds the rated pressure difference, the solenoid valve should be stopped, the manual valve is closed before and after, so as to avoid the explosion and leakage of the solenoid valve.

 

Ordering instructions

 

1, when ordering, please specify type, nominal diameter, nominal pressure, working medium, working pressure difference, medium temperature, power supply voltage and power, medium viscosity.

 

2, the solenoid valve normal operation voltage is 220

+22

V, if exceed this range, please indicate voltage fluctuation when ordering. Other specifications supply voltage can be a special order.

-15

 