Menu

Connect with us

Eaton MGE UPS power EatonS11DX1000C tower EDX1000CXL host 1KVA long machine

Eaton MGE UPS power EatonS11DX1000C long lasting model host MGE 1KVA, MGE MGE UPS power, national package, special direct sales

price:USD$1780.00
discount 70% in 2018-10-19 to 2018-10-21
price: USD$ 1246.00
freight :USD$18.00,(Express)
freight :USD$7.00,(Postal parcel)
views:0
Search Similar or mail to saler or send message to saler

Pay with PayPal, PayPal Credit or any major credit card

EatonmgeUPS power supply

EatonS11DX1000C long term mainframe

MGE 1KVA,

MGE MGE UPS power supply

National parcel postSpecial direct selling

  

mgeUPSModel specification

capacity

Reference quotation

MGE UPS-Pulsar DX1000VAStandard machine
(built-in)3only12V-7AHBattery,No external battery

1KVA-Output full load power700W

1950.00(spothitpurchasebuy)

MGE UPS-Pulsar DX1000CLong machine
External battery must be connected, external battery voltage must be applied:36V

1KVA-Output full load power700W

1780.00(Click purchase)

MGE UPS-Pulsar DX2000VA Standard machine
(built-in)8only12V-7AHBattery,No external battery

2KVA-Output full load power1400W

4280.00(Click purchase)

MGE UPS-Pulsar DX2000CLong machine
External battery must be connected, external battery voltage must be applied:96V

2KVA-Output full load power1400W

3620.00(Click purchase)

MGE UPS-Pulsar DX3000VAStandard machine
(built-in)8only12V-7AHBattery,No external battery

3KVA-Output full load power2100W

4730.00(Click purchase)

MGE UPS-Pulsar DX3000CLong machine
External battery must be connected, external battery voltage must be applied:96V

3KVA-Output full load power2100W

4260.00(Click purchase)

MGE UPS-Pulsar DX6000VAStandard machine
(built-in)20only12V-7AHBattery,No external battery

6KVA-Output full load power4200W

12150.00(Click purchase)

MGE UPS-Pulsar DX6000CLong machine
External battery must be connected, external battery voltage must be applied:240V

6KVA-Output full load power4200W

8500.00(Click purchase)

MGE UPS-Pulsar DX10KVAStandard machine
(built-in)20only12V-7AHBattery,No external battery

10KVA-Output full load power7000W

15660.00(Click purchase)

MGE UPS-Pulsar DX10KC S11Long machine
External battery must be connected, external battery voltage must be applied:240V

10KVA-Output full load power7000W

12160.00(Click purchase)

MGE UPS-Pulsar DX10KC S31Long machine
External battery must be connected, external battery voltage must be applied:240V

10KVA-Output full load power7000W

16680.00(Click purchase)

MGE UPS-Pulsar DX15KC S31Long machine
External battery must be connected, external battery voltage must be applied:240V

15KVA-Output full load power10.5KW

23668.00(Click purchase)

MGE UPS-Pulsar DX20KC S31Long machine
External battery must be connected, external battery voltage must be applied:240V

20KVA-Output full load power14KW

24500.00(Click purchase)

MGEupsThe power supply only refers to the customer reference price, the purchase price, welcome to call!

 

MGE UPS power detail parameters
MGE 1-3k parameters

Model /wDX 1000/700DX 2000 HV/1400DX 3000/2100
Standard machineEDX1000CEDX2000CEDX3000C
Long machineEDX1000CXLEDX2000CXLEDX3000CXL
technologyDual conversion IGBT with micro controller
Rated input voltage220V 
Input voltage range122-300V 
Nominal Output Voltage220V 
Battery power output voltage220V 
frequency50/60Hz, automatic detection
Data line protectionAn input / output jack for surge protection of telephone / modem / Internet lines is included
output jack4 IEC types (3K provides hard wire terminals)
Input connectionRemovable 1.5MIEC input cable (cable included in the supply)
Battery
Battery typeSealed lead acid battery (12V)
Battery quantity388
Charging capacity5 hours charge to 90% (LV1K-3K standard) /7 hours charge to 90% (LV6K standard)
8 hours to 90% capacity (LV10K and HV standard)
Battery monitoringBattery change indicator light
Boot up when battery power supplyThe device can be started without AC mains supply - it can be used as a handheld power supply
user interface
visionIn the city power, battery, inverter, bypass and load mode operation / battery charging level
Alarms and controls
Sound and light alarmBattery operation mode, battery low power, general fault, overload, bypass operation
controlTwo buttons for on / off and off alarm
Communication / management
Power management softwareWINPOWER power management software, on the CD
line typeStandard RS232
SNMP interfaceOptional SNMP card
Environmental Science
working temperature0oC ~ 40oC
humidity<95%
Noise level<45dB (LV1K-1.5K) /<50dB (other)
standard
AuthenticationCE, UL (only low pressure: 1K-3K), ISO9001
Size and weight WxHxDmm
size145x200x400145x200x465192 x 340 x 460
Weight kg14 (XL: 7)32 (XL: 15)35.5 (XL: 16)

* high performance, high reliability
DX uses high-frequency technology to provide users with a perfect sine wave output of small UPS.

Automatic bypass
In the case of overload or UPS fault, DX will automatically transfer the load to the mains AC power supply.

* online dual conversion layout
This layout can maintain a high level of power quality, regardless of the interference from the distribution waveform in the conversion process from AC to DC and from DC to AC, the battery is only used as standby power supply.

* wide input voltage range
The input voltage range of DXUPS is up to 120-300V, which can improve the compatibility with the engine driven generator set and reduce the frequency of switching to the battery power supply. The battery is only used in the most serious event, so that the available standby time is the maximum and the life of the battery is prolonged.

* advanced communications
With a RS232 port, it is convenient to connect the UPS to the server, which can be used for local monitoring. It also has an alternative UPS card for network management.
Monitoring software can be used for
Prompt users when power events or predetermined conditions occur
- automatically shut down the user's server
Remote monitoring control UPS
* high performance battery charger
DX battery charger:
Shortening battery charging time
Protect the battery from damage due to excessive discharge
By adjusting the power factor to prevent interference to the distribution system
Prevent transmission faults (feedback protection) on the distribution system

Cold start with battery
This power ensures that your application device has no fault even when the power failure occurs.

* standby time varies from 5 minutes to several hours
DXUPS provides full load 5-8 minutes of standard standby time to protect application equipment. With the XL device, you can get several hours of running time with an external battery

'