Menu

Connect with us

Dual battery 6-GFM-20012V200AH/UPS/EPS special battery DC screen

price:USD$1280.00
discount 70% in 2018-10-21 to 2018-10-23
price: USD$ 896.00
freight :USD$18.00,(Express)
freight :USD$7.00,(Postal parcel)
views:0
Search Similar or mail to saler or send message to saler

Pay with PayPal, PayPal Credit or any major credit card

Applicable scopeWind energy: solar battery; battery; UPS battery; communication power batteries; batteries; battery railway; battery locomotive; lead-acid batteries; battery air; water batteries; geological batteries; medical appliances continued; battery for rail traffic

Dual marketing concept:
To promote credibility, after selling products.
Dual market concept:
The market is the market can create the workshop.
Dual service concept:
The energy of uninterrupted service without limit; fast, efficient, responsible, professional service; human occupation morality is dual, service is the culture of Shuangdeng brand value, service is the dual corporate social responsibility.
The five principle:
The task is to meet customer needs and solve problems; time and place; attention and work; the important analysis is to grasp the opportunity of service; efficiency of service demand response.

6-GFMType VRLA battery, is a new type of high energy battery is developed with the advanced technology, in line with the performance indexYD/T799-2002andIECStandard. The product has the advantages of safe and reliable seal, high specific energy, small resistance, low self discharge rate, charge acceptance ability, long cycle life, sealing the advantages of high reaction efficiency. No free electrolyte during normal use, no acid mist overflow, convenient maintenance, can be widely used in telecommunication systems, uninterruptible power supply (UPS), fire and security systems, emergency lighting, mobile measurement equipment, power systems, instrumentation, military, railway systems, automatic control alarm equipment etc..

Dual battery type table:

Model

Voltage

(capacityAh

Sizemm

The weight is about (kg

Packing number

long

wide

high

Total height

6-GFM-24

12

24

165

125

167

175

8.20

2

6-GFM-38

12

38

197

165

167

174

13.20

2

6-GFM-65

12

65

325

166

167

171

21.00

1

6-GFM-100

12

100

331

174

214

218

32.00

1

6-GFM-150

12

150

471

174

225

229

43.00

1

6-GFM-200

12

200

502

211

225

229

62.00

1


The main technical indicators:25Under the conditions of normal use, floating life up to8Year;

Battery leakage in use, does not produce mist during use, do not need to add acid water;

Self discharge:4%2528day

Deep cycle life:60080%DOC;

Working environment temperature:-15-+45

The sealing reaction efficiency:greater than96%

Product features: high strengthABSThe plastic shell has the characteristics of good impact resistance and vibration performance;

Special lead based alloy grid (ZL01277477.7), small resistance, corrosion resistance and good charge acceptance ability.

New process of plate production, active material utilization rate is high.

High quality superfine glass fiber membrane, good performance of high current discharge.

High purity electrolyte additive special small self discharge

Multi layer seal technology and special seal to ensure no leakage.No mist escapeSafe and reliable.
Battery installation:
1.Battery shelves, do not move the pole and the exhaust plug, please hold the battery into the battery holder (bottom up, pay attention to confirm whether the battery polarity corresponding to the right);
2.Please do not be arranged when installing the battery polarity (+), (-) reverse connection, such as the reverse may cause fire damage to batteries and chargers.
3.Connect the battery before, please use the fine wire brush brush clean full terminal, in accordance with the battery connection graph are connected in series and parallel lines.
4.To connect two adjacent single batteries in the battery terminal, please apply lead-acid battery anti rust agent (Vaseline), and then by bolts and nuts and battery terminals connecting bar or wire connection. Tighten at later, coated with a thin layer of antirust agent in bolt nut and contact connection conductor. If the battery not coated with anti rust agent, will cause the corrosion layer produced high impedance.
5.Then connect the battery between layers of positive and negative.
6.After the completion of the total battery voltage check connection is correct (the total voltage of batteryVtotal=Single battery voltageVsingle×The total number of batteriesNTotal), voltage correct after the battery and charger. It is sub battery charger, negative sub battery charger connected to the negative sub. The connection is completed, check the battery and charger has no connection between error and connecting line is loose etc..

Be careful:
1.Install the battery before, please carefully read "battery installation manual.". Please carefully read after storage, to flexible use. In addition, if not understand the place or to discuss technical problems, please contact our customer service service department.
2.Installation error, danger of leakage, electric shock, damage to the batteries.
3.Move the battery before you touch a grounded metal object, released in may exist in the human body electrostatic charge.
4.Move, shift the battery press weight, otherwise it may cause pain and trauma. Handling the battery, please don't mention, pull the battery positive and negative, otherwise there is a danger of battery breakage, leakage.
5.Handling the battery gently, please be careful not to damage the battery, such as collision, roll or throw, otherwise there is a danger of damage to the batteries.

Notice:
1.Please don't let the bananas contain volatile oil, water, organic solvent such as gasoline detergent, contact tank shell and lid. Otherwise it will cause the battery shell cracking, fine cracks, leading to leakage of acid.
2.Put a wrench, pliers and other metal tools ban battery. Otherwise, there is a danger of burns, cause a short-circuit battery damage.
3.Install insulation cover correctly in the terminal part of the battery, the connecting conductor and bolt, nut, or risk of electric shock. If not properly installed, when the short circuit occurs, may cause burns, fire and explosion damaged battery.
4.Tighten the bolts and nuts, please according to the provisions of the torque tightening, or they may have a spark or damaged terminal.