UPS uninterruptible power supply host CSTKC6KS6KVA4800W long delay external battery, original genuine

High frequency on line external 192V battery pack

price:USD$2650.00
discount 70% in 2018-10-21 to 2018-10-23
price: USD$ 1855.00
freight :USD$18.00,(Express)
freight :USD$7.00,(Postal parcel)
views:0
Search Similar or mail to saler or send message to saler

Pay with PayPal, PayPal Credit or any major credit card

C6KS (6000VA4800W) on line sine wave UPS uninterruptible power supply, the main function of the regulator needs external (long acting machine) DC 192V use

 

[power] 6000VA4800W

Battery external connection

[warranty] three years free warranty

[name of factory] Foshan Dsy technology Ltd

[DC voltage] DC192V

 

Product Brief
C6K (S) ~ 3C20KS is widely used in all aspects of information collection, transmission, processing, storage and application, and its importance is increasing with the increasing importance of information applications. C6K (S) ~ 3C20KS provides a full range of scalable functions, which can be flexibly configured according to users.

Product specification
Machine model
C6K
C6KS
C10K
C10KS
3C10KS
3C15KS
3C20KS
Size (width, depth, height, height) mm
248×500×616
240×500×460
248×500×616
240×500×460
248×500×616
Net weight (Kg)
57
18
67.5
20
27
35
35
power
Apparent power (KVA)
6KVA
6KVA
10KVA
10KVA
10KVA
15KVA
20KVA
Active power (KW)
4.8KW
4.8KW
8KW
8KW
8KW
12KW
16KW
AC input
Input mode
Single phase grounding
Voltage range
120VAC~275VAC±5V
Bypass voltage
80VAC×(1±5%)~285VAC(1±5%)
Current *
33A.max
37A.max
55A.max
59A.max
86A.max
112A.max
frequency range
46Hz~54Hz
power factor
0.99
0.95
output
 
 
 
 
 
 
 
Output mode
The single-phase grounding | three-phase four wire + wire
Voltage
220VAC * (1 + 1%) inverter output
Electric current
27A
45A
68A
91A
frequency
46Hz ~ 54Hz (city power mode, followed by city power), 50Hz * (1 + 0.1%) (battery mode)
power factor
0.8
Overload capacity
105% to 125%, 1 minutes after the bypass, 125% to 150%, 30 seconds after the bypass, 1 minutes after the broken output; >150%, 0.5 after bypass
Peak factor
3:1
Distortion degree
THD<2% (linear load)
Battery (battery used at high temperature, life will decline sharply)
Battery voltage
Standard 192VDC (customized for 240V)
Battery capacity x quantity
12VDC x 16 section (can be customized for 20 sections)
Backup time
4 minutes (full load)
Depends on the capacity of the external battery
3 minutes (full load)
Depends on the capacity of the external battery
Charging time
7 hours charge to 90%
Depends on the capacity of the external battery
7 hours charge to 90%
Depends on the capacity of the external battery
Communication and monitoring function
 
RS232 (can turn 485), dry nodes, smart slot (scalable SNMP, SMS and other monitoring methods)








The maximum current is UPS input 187V, the output is full load, the charger is under full load working condition.



Note: the product should be in kind. Product design, technical specifications updated without notice.

 
...........
......
.........