Emerson - Liebert UPS power UL330200L three three 20KVAUL330200L long machine

price:USD$71699.00
discount 70% in 2018-10-17 to 2018-10-19
price: USD$ 50189.30
freight :USD$18.00,(Express)
freight :USD$7.00,(Postal parcel)
views:0
Search Similar or mail to saler or send message to saler

Pay with PayPal, PayPal Credit or any major credit card

Emerson UPS power supply model UL330200L-UL330600L detailed description of parameters

Uses:
Emerson network power launched UL33 three phase input and output power UPS, double DSP full digital control, input and output are using high frequency PWM rectifier inverter digital control technology, is the world's second application of this leading technology products. UL33 series UPS system is suitable for uninterrupted use of electric field. It is mainly used as uninterrupted power supply system for various computer rooms. It is widely used in financial, securities, post and telecommunications, government agencies, energy, chemical industry, transportation and other industries.
Technical index:
Technical index:
Product features
The influence of the unstable factors such as surge, voltage transients and noises on the normal operation of the load is analyzed.
Professional design for overall improvement of system reliability
The fourth generation insulated gate bipolar transistor (IGBT) power devices and multiple protection technologies are adopted
The advanced double DSP full digital technology, the whole machine does not need any adjustable resistance, strong anti-interference ability, no aging drift problem
Advanced distributed direct parallel technology ensures online expansion and system redundancy
The instantaneous digital current sharing technique significantly reduces the <1A of the combined system, and the current unbalance is less than 1%
Good electromagnetic compatibility design
Adopt high power devices Yuliang, enhance the ability to adapt to the grid
The unique UPS lightning protection technology in the industry, built in D class lightning protection
Excellent input characteristics
The ultra wide input voltage range (-45% ~ +15%) can be adapted to harsh grid conditions
Wide frequency input range (50Hz10%) ensures the stable operation of UPS when the generator is powered
Advanced six tube IGBT high frequency rectification technology, without additional external equipment, the input power factor can reach more than 0.99
The application of instantaneous waveform control technology greatly reduces the input current harmonic (iTHD<3%)
Low DC bus ripple and extend battery life
Excellent output characteristics
The inverter adopts high precision vector control technology, the output voltage regulator has high precision, fast dynamic response, and low distortion rate
The inverter has the ability to carry 100% unbalanced loads
Inverter has strong overload capability and shock resistance
The output of the delta /Z0 isolation transformer, effectively suppress the harmonic distortion of the output voltage
Single line, stand-alone ECO, master / slave hot backup and redundancy, expansion and parallel machines and other modes of operation, fully compatible with hardware and software
Reliable digital control, distributed intelligent parallel machine technology
Intelligent battery management
According to the battery discharge curve, the discharge terminal voltage can be automatically regulated to avoid the excessive discharge of batteries caused by the fixed setting
The intelligent charging and discharging battery management based on temperature compensation greatly prolongs the service life of battery more than 50%
Regular automatic battery self-test to ensure reliable battery operation
Accurate prediction of battery backup time
Fully automatic battery management to reduce maintenance work
Complete local monitoring management
The original adaptive UPS parallel layer communication, without any additional equipment, can be monitored by any UPS and UPS system information
The single machine provides 8 output and 6 input relay contacts
Support RS232, RS485, SNMP, MODEM a variety of back office communication
Super network management function
The system has the functions of battery discharge warning and automatic safety shutdown
Advanced SNMP card and its related software, compatible with 10M/100M Ethernet, support SNMP, HTTP, TFTP, TELNET, TTYP and other protocols, monitoring software with power event recording and analysis functions, flexible networking program, can be realized on the Internet/Intranet remote monitoring
The UPS system has self diagnosis and protection function, can realize the automatic E-mail and beeper sound and light alarm, alarm
The network can monitor up to more than 60 thousand UPS and support Wan solution at the same time
The man-machine interface is friendly, easy to operate and maintain
All Chinese large screen LCD display, Chinese and English optional operating interface
Simple operation, "one button boot""
Support remote, automatic boot, unattended
Modular circuit structure, full frontal operation, easy to use and maintain

Basic technical parameters

capacity

20kVA

30kVA

40kVA

60kVA

Model

UL33-0200L

UL33-0300L

UL33-0400L

UL33-0600L

Main path input

input voltage

380V (line voltage)

Input mode

Three phase three wire

power factor

>0.99

harmonic current

<3%

Voltage range

+15% ~ -45%

-20%~-45% derating between 100%~50

frequency range

50Hz ±10%

Bypass input

input voltage

380V (line voltage)

Input voltage range

±10%

Input mode

Three phase four wire

frequency range

50Hz±10%

transport

A

Steady state voltage accuracy

(balanced load)

±1%

Dynamic voltage transients

1% (50%~100%~50% load change)

Dynamic transient recovery time

0

Voltage distortion (linear load)

THD<1%

Voltage distortion (nonlinear load)

THD<3%

power factor

0.8 (lag)

frequency range

50Hz±2Hz

Frequency accuracy (battery inverter)

±0.02%

Three phase difference

120 + 0.5 degrees (balanced or unbalanced load)

100% unbalanced load voltage unbalance

±1%

Frequency tracking rate

<1Hz/s

Overload capacity of inverter

When 105%< is loaded with <125%, 10 + 0.1min is converted to bypass output;

When 125%< is loaded with <150%, the bypass output is turned in 1 minutes;

When >150% is loaded, the bypass is output immediately after 200ms

Bypass overload capacity

135% rated current can overload for a long time

1000% rated current 20ms (static switch selection standard)

Peak to peak output current ratio

3:1

Switching time (normal mode)

0

system

The

System efficiency (linear load)

90%

90%

91%

92%

Battery inverting efficiency (linear load)

93%

93%

94%

95%

display

LCD+LED

EMC/EMI

conduction

EN50091-2

radiation

EN50091-2 CLASS-A

harmonic current

IEC1000-3-4

Immunity

EN 61000-4-2.3.4.6.8.9.11 Level III,

EN 61000-4-5 Level Ⅳ

MTBF (single machine system)

1 million 200 thousand hours (MTTR=4 hours)

Safety requirements

CCEE

Noise (2m)

<55dB

<55dB

No load circulation (1+1)

<1A

      

Current unbalance (1+1)

<1%

Current unbalance (3+1)

<2%

insulation resistance

>2M(500VDC)

Insulation strength

(input, output to ground) 2820Vdc, 1min without arcing

surge protection

Meet the requirements of class IV installation location specified by IEC60664-1, that is, the ability to withstand 1.2/50us+8/20us mixed wave is not less than 6KV/3KA

Protection grade

IP20

Battery section number

30 section of 12V battery

Weight kg

440

528

654

811

Physical size (W*H*D) mm

600*1400*860

600*1400*860

800*1800*860

800*1800*860


 

Matters needing attention:

1) the use of UPS environment should pay attention to good ventilation, conducive to heat dissipation, and keep the environment clean.
2) do not bring inductive load, such as currency counter, fluorescent lamp, air conditioning, etc., so as not to cause damage.
3) the output load of UPS is controlled at about 60%, and the reliability is the highest.
4) UPS carrying too light (such as 1000VA UPS band 100VA load) may cause deep discharge of the battery, will reduce the battery life, should be avoided as far as possible.
5) appropriate discharge, contribute to the activation of the battery, such as long-term stop electricity, every three months should be UPS with artificial broken electricity load discharge time, so you can extend the service life of the battery.
6) for the majority of small UPS work, open UPS, boot to avoid load startup, the work should be closed for UPS; the network room UPS, because most of the network is 24 hours of work, so UPS must also be all-weather operation.
7) UPS discharge should be charged in time to avoid damage to the battery due to excessive self discharge.

Warranty service content:

1, our store sales products enjoy the factory standard warranty period and warranty service

2, the warranty period provided by us free repair or replacement service (shipping by the buyer)
          
3, our shop provides free technical advice and troubleshooting; if you need engineers to install, debug or repair, you need to collect the corresponding travel expenses and installation fees.

If it is one of the following circumstances, it is not included in the warranty:

A does not operate and use according to the user's manual;

B failure to change the machine without consent;

C natural disasters, earthquakes, lightning and human irresistible natural factors

Reminder:

The products sold by the company are all 100% new original formal products, and never sell second-hand or refurbished products!

Taobao store profit, focus on the amount of goods sold, "three packs" period, back and forth freight, buyers themselves, please understand!

The products sold by Taobao store do not contain invoices, such as invoice plus 6% tax point!

Invoice should be paid by public account, and the purchase contract can be signed with customer service"!

Suggest that buyers use the Alipay payment, which is convenient, and can give you security!

Special tips:

BecauseUPSFor bulky items,Freight collection!Occasionally manufacturers price changes can not be adjusted in time, please know, thank you for your cooperation! Certified goods. Thank you for coming! ~

..........
............
........
.......