Menu

Connect with us

Danfoss frequency converter FC301P7K5T4E20H2XGCXXXSXXXXAXBX7.5KW

price:USD$4915.00
discount 70% in 2018-10-16 to 2018-10-18
price: USD$ 3440.50
freight :USD$18.00,(Express)
freight :USD$7.00,(Postal parcel)
views:0
Search Similar or mail to saler or send message to saler

Pay with PayPal, PayPal Credit or any major credit card

 

Automation DriveRepresents a concept, namely through the single transducer to control any machine or production line from the standard to the entire operating range of the servo. Intelligent plug technology and the reliability of the inverter operation There is nothing comparable to this, let be a game like simple.

Danfoss FC301The inverter inverter module design, realization of each component is inserted. Provide magnetic flux vector control, realize the control from simple to complex drive servo operation.

Danfoss FC301Frequency converterFC300 VLT AutomationDriveRepresents a transducer concept, namely, by single transducer to control any machine or production line from the standard to the entire operating range of the servo.

Danfoss FC301Frequency converterFC300 VLT AutomationDriveBased on the modular open technology platform makes it has great adaptability and programmable ability. Have a configuration and easy operation interface, support local language and character. We use intelligent plug technology and the reliability of inverter operation There is nothing comparable to this, let the children become like a simple game.

The chart shows
The letters and symbols.

Can display bar charts and graphs.
Easy to observe.

With six standard language (also can use the local language).

The range of products
200-240 V ..... 0.25 kW - 45 kW(FC301/FC302)
380-500 V ..... 0.37 kW - 450kW(FC312)
380-500 V ..... 0.37 kW - 1000kW(FC302)
525-600 V ..... 0.75 kW - 90 kW(FC302)
525-690 V ..... 37 kW - 1400 kW(FC302)

The case meets the IP20/ requirements of the chassis frame frequency converter. The optional IP21/NEMA1, IP55/NEMA12, IP54/NEMA12 or IP6NEMA4x. Intelligent logic controllerVLT AutomationDriveThe standard of intelligent logic controller, can perform more than 20 different steps through logic operation cycle.

SafetyVLT Automation
VLT AutomationDriveThe standard provides a safe stop function (for EN954-1 standard third installation). This function can prevent the accidental start-up of inverter. Hot swappable LCP local control panel (LCP) plug at run time. The control panel can be easily set from a transducer (or from the installation of software set PC) transmitted to another transducer. Intelligent thermal management currently has three cooling methods, which have their own advantages. Forced convection cooling fan: the cold air to the aluminum heat sink to remove heat. At this point you can easily clean the cooling channels are not in contact with the electronic components of the case. Cooling: cooling plate can be external cooling through the aluminum shell on the back of the. Air cooling cold air from the control room or outside the cooling fins are not in contact with the electronic components of the case.

The menu structure

The design matrix system model based on the famous VLT inverter.

Shortcut keys for experienced users can use simple operation.

At the same time editing and operation in different settings.

shortcut menu

A Danfoss defined shortcut menu.

The shortcut menu for a user defined.

A user to modify the menu in the list of application specific parameters.

A "application settings menu" to set some special application more simple and fast.

New key

The Info button provides a built-in user manual.

The Cancel button can cancel the previous operation.

The Alarmlog provides fast access function.

Light indicator

The selected key with luminous indication when activated.

Other advantages

In the process of operation can be disassembled.
Have the upload and download function.
Protection level can have a IP65 in the panel on the door.
A removable fan
As most of the components, the fan can be rapidly disassembled and cleaned.

Chassis
The inverter to meet the IP20/ requirements of frame chassis. The optional IP21/NEMA1, IP55/NEMA12, IP54/NEMA12 or IP66NEMA4x.

Intelligent logic controller
VLTAutomation Drive FC 300The standard provides a safe stop function (for EN954-1 standard third installation). This function can prevent the accidental start-up of inverter.

Safety
VLT Automation Drive FC 300The standard provides a safe stop function (for EN954-1 standard third installation). This function can prevent the accidental start-up of inverter.

Hot swap LCP
The local control panel (LCP) plug at run time. The control panel can be easily set from a transducer (or from the installation settings software PC) transmitted to another transducer.

Intelligent thermal management
There are two types of cooling, they have their own advantages. Forced convection cooling fan: the cold air to the aluminum heat sink to remove heat. At this point you can easily clean the cooling channels are not in contact with the electronic components of the case. Cooling: cooling plate can be external cooling through the aluminum shell on the back of the. Air cooling cold air from the control room or outside the cooling fins are not in contact with the electronic components of the case.

Enclosure
Use VLT Automation Drive FC 302 When you can according to their own needs with a wide range of accessories. For more information, please refer to the operating instructions.

Option
Bus communication, synchronization, user settings options can be used for a variety of plug and play.

Display options
The graphical local control panel (LCP102)
Digital local control panel (LCP101)
Installation kit LCP panel

Application options
External 24V power supply card
Field bus.
PROFIBUS DP V1 (MCA 101)
Profisafe-Stop (MCA 103)
DeviceNet (MCA 104)
CAN open loop (MCA105)
Ethernet IP (MCA121)

The I/O option
General I/O (MCB101)
Encoder input (MCB102)
The parser input (MCB103)

Relay options (MCB105)
The safety of PLCI/O (MCB108)
PTC thermistor card (MCB112)

Motion control.
Motion control (MCO305)
Synchronous control (MCO350)
Position control (MCO351)
Center winding controller (MCO352)

braking
Braking resistor
For the installation of accessories and installation of box resistor

Wave filter
Harmonic filter (AHF005/010MCE)
Sine wave filter (MCC101)
DU/dt filter (MCC102)

24 - hour service hotline: 13818754396 Li Gong

........