Emerson PS48300, Emerson 48V300A Emerson indoor indoor power cabinet, cabinet 300A NEW

price:USD$6000.00
discount 70% in 2018-10-17 to 2018-10-19
price: USD$ 4200.00
freight :USD$18.00,(Express)
freight :USD$7.00,(Postal parcel)
views:0
Search Similar or mail to saler or send message to saler

Pay with PayPal, PayPal Credit or any major credit card

Emerson PS48300, Emerson 48V300A Emerson indoor indoor power cabinet, cabinet 300A NEW

Contact: Zhou Qing

Tel: 15321333136

 Technical parameters of power system
3.1 PS48300-3B/2900The system has the following2Configuration:
1).PS48300-3B/2900-X1Dual input, no user manual AC AC output, DC output7The road;
2).PS48300-3B/2900-X2Two: AC automatic user input, AC output, DC output7The road.

 

PS48300-3B/2900-X1

PS48300-3B/2900-X2

Monitoring moduleM500F

1platform

Rectifier moduleR48-2900

Standard configuration:2The number of optional units:212platform

AC power distribution

lightning protection

II/CLightning protection

AC input

Two input AC, AC input circuit breaker specifications:
2×63A/2P

AC output

No user AC output

Two three pin socket, by the way16A/1PTheMCBcontrol

DC distribution

lightning protection

DC lightning

Battery

Two battery input fuse:2×100A NT00

Output load

7The road load output, the total load current≤100A. Among them:
1×63A/1PMCB),2×32A/1PMCB),1×10A/1PMCB),1×100A NT00FUSE),1×50A NT00FUSE),1×6A NT00FUSE

Optional components

The temperature sensor and the cable,DC/DCModule, remote monitoring module

 

 
4.  Detailed technical indicators of the power system:

Parameter category

Parameter name

PS48300-3B/2900

environment condition

working temperature

-540

Storage temperature

-4070

relative humidity

595RH

Altitude

≤2000m(more than required derating)

Other

There is no conductive dust and corrosive gas, no danger of explosion

AC input

Input format

Single-phase three wire

Rated input voltage

380V

Input voltage range

PS48300-3B/2900-X1285475Vac(error:5Vac
PS48300-3B/2900-X1285475Vac(error:5Vac

The input AC voltage frequency

4565Hz

***Large input current

≤46A

power factor

≥0.99

DC output

The output DC voltage

42.257.6Vdc

DC output current

0120A

stabilized voltage precision

≤1

efficiency

≥88

The peak to peak noise voltage

≤200mV020MHz

Call weighted noise voltage

≤2mV3003400Hz

Wide band noise voltage

≤100mV3.4kHz150kHz);≤30mV150 kHz30MHz

Discrete noise

≤5mV3.4kHz150kHz);≤3mV150kHz200kHz);≤2mV200 kHz500kHz);
≤1mV0.5MHz30MHz

AC input alarm and protection

AC input overvoltage alarm point

The default value280±5VacThe monitoring module can be set.

AC input overvoltage alarm recovery point

The default value270±5VacBelow, the AC input overvoltage alarm point10Vac

AC input undervoltage alarm point

The default value180±5VacThe monitoring module can be set.

AC input under voltage alarm recovery point

The default value190±5VacThat is higher than the AC input undervoltage alarm point10Vac

Overvoltage protection switching point*

285Vac±5Vac

Switching overvoltage recovery point

270Vac±5Vac

Undervoltage protection switching point

170Vac±5Vac

AC input alarm and protection

Under the recovery point pressure switch

185Vac±5Vac

Undervoltage protection

125Vac±5Vac

Under the recovery point pressure protection

140Vac±5Vac

DC output alarm and protection

DC output overvoltage protection

The default value59.0±0.2Vdc

DC output overvoltage alarm point

The default value58.5±0.2Vdc   The monitoring module can be set

DC output overvoltage alarm recovery point

The default value58.0±0.2Vdc    Below the overvoltage alarm point0.5Vdc

DC output undervoltage alarm point

The default value45.0±0.2Vdc    The monitoring module can be set

DC output under voltage alarm recovery point

The default value45.5±0.2Vdc    Above the undervoltage alarm point0.5Vdc

Battery protection action point

The default value43.2±0.2Vdc    The monitoring module can be set

Rectifier module

Flow characteristics

Rectifier module and machine can work, and according to the load load sharing ability, the unbalanced degree should be better than±3% of the rated output current value; test current range10%~100% of rated current

The input power (45℃)

176VacThe input module, output power for * * *100% of rated power, i.e.1740W
110VacThe input module, output power for * * *50% of rated power, i.e.1050W
85VacThe input module, output power for * * *44.4% of rated power, i.e.800W

Rectifier module

Overvoltage protection mode

The rectifier module output overvoltage protection hardware and software output overvoltage protection, overvoltage protection for hardware59.5V±0.5VBetween the hardware, overvoltage protection after the need for manual intervention can boot. Software protection can be used by the monitoring module settings, set the range5659V(ratio of high output voltage0.5VAbove, the factory default value59V
The software has two kinds of overvoltage protection mode, can through the background maintenance software selection:
1An overvoltage lock mode.
When the output rectifier module to software protection after shutdown rectification module and maintain, the need for manual intervention before resuming work;
2Two. Overvoltage lock mode
Rectifier module software protection after shutdown5Seconds reboot, if within a set time (the default is5Minutes, can monitor the module settings) occurred second times over voltage, rectifier module is shut down and keep the need of manual intervention to boot. Artificial intervention methods: by monitoring module reset rectifier module, can also pass from rectifier module from power system to reset

Output slow start function

The boot module instantly, the output voltage can be increased slowly and the rise time can be set

The fan speed can be set

The speed of the fan module can be set to automatically adjust, can also be set to full speed

The temperature limit of power

45The following C ambient temperature, full power module1740WOutput;
45C above the ambient temperature, using the linear power module output limit, which:
55At ambient temperature, the output power of the module1450W65At ambient temperature, the output power of the module1160W
70At ambient temperature, the output power of the module is zero

EMCindex

Conducted emission

Class A     Reference standard:EN55022

Radiation emission

EFT

Level 4     Reference standard:EN61000-4-4

ESD

Level 3     Reference standard:EN61000-4-2

surge

Level 4     Reference standard:EN61000-4-5

radiated immunity

Level 2     Reference standard:EN61000-4-3

Conducted immunity

Level 2     Reference standard:EN61000-4-6

Anti lightning performance

The AC side anti lightning characteristics

The AC input side can withstand the lightning impulse voltage waveform simulation10/700μsThe amplitude is,5kVThe polarity of the impact5A simulation of lightning impulse current waveform;8/20μsThe amplitude is,20kAThe polarity of the impact5Time, and can withstand8/20μsSimulation of lightning current40kA1Time. Each time interval is not less than the impact test1min

DC side anti lightning performance

The DC side can withstand lightning impulse current waveform simulation8/20μsThe amplitude is,10kAThe impact of time

Other

Safety

accord withIEC60950-1:2001standard

Noise

At ambient temperature for25C, not more than55dBA

insulation resistance

The temperature at1535Temperature, relative humidity≤90RHIn the environment, to test the DC voltage500VAC and DC circuit, circuit of AC part, is not less than the insulation resistance of the DC part10MΩ

Insulation strength

The test should be temporarily removed lightning protection unit, monitoring module and rectifier module, AC circuit of DC circuit can withstand50HzEffective value3000VacOne minute of AC voltage, leakage current≤10mANo breakdown, no flashover phenomenon.
AC circuit to ground can withstand50HzEffective value2500VacOne minute of AC voltage, leakage current≤10mANo breakdown, no flashover phenomenon.
DC circuit can withstand the50HzEffective value1000VacThe AC voltage for a minute, leakage current≤10mA, no breakdown, no flashover.
The auxiliary circuit is not directly connected with the main circuit can withstand50HzValid values are,500VacThe AC voltage for a minute, leakage current≤10mANo breakdown, no flashover phenomenon

Other

MTBF

200 000hr

ROHSRequirement

satisfyRoHSIn the instructionR5The requirements of

Mechanical parameters

The size (mm

Cabinet

600(width)×600(Shenzhen)×2000(high)

Monitoring moduleM500F

87(high)×85(width)×287(Shenzhen)

Rectifier moduleR48-2900

87.9mm(high)×85.3mm(width)