EAST EAST EA660 modular UPS 25KVA uninterruptible power supply capacity of single module support hot plug

price:USD$28800.00
discount 70% in 2018-10-19 to 2018-10-21
price: USD$ 20160.00
freight :USD$18.00,(Express)
freight :USD$7.00,(Postal parcel)
views:0
Search Similar or mail to saler or send message to saler

Pay with PayPal, PayPal Credit or any major credit card

EAST EA660 Series modular UPS

 

The EA660 series is easy to launch a new three three modular UPS, modular product design and N+X parallel redundancy technology, product coverage and capacity 20KVA to each power segment between the 250KVA module; the internal use of "modular" design, both to ensure the layout of the compact and increase the reliability of the whole machine and cabinet room module; the design of hot swap. EA660 series UPS with 5.7 inch touch screen LCD menu design and architecture, all kinds of information can be monitored by UPS LCD, all operations at a glance. EA660 UPS series with independent intelligent charging module; number of each battery section battery from the 40 to the 32 section optional.

 

 80-250K图片1

Power range:

20KVA - 250KVA

 

Application field:

The data processing center, computer room, telecommunications, finance, securities, taxation, transportation, medical and industrial automation

 

 

 

The 4.1 basic components, EA660 series products

EA660 series of modular UPS system is composed of power module, charging module and system monitoring module, and battery cabinet group.

1): power module power module is the core part of the whole system, which already has a complete function of UPS power module; the input power by the unstable internal rectifier, PFC power factor correction circuit, inverter into pure, stable power supply to the load power supply.

The following diagram:功率模块2

 

Its characteristic is:

The design of double transform 2 online, to ensure the quality of output;

Each module has 2 independent digital intelligent control;

2 each module can work independently;

2 each module has independent bypass system;

2) charging module: EA660 system configuration independent intelligent charging module, using full digital control, single charging module maximum charging current of 30A, provides the intelligent battery management and perfect protection function for the battery, prolonging the service life of the battery. The following diagram:

    充电模块3

   




Its characteristic is:

2 charging voltage and current can be adjusted according to the number and capacity of the external battery;

The 2 section has three unique charging mode, the first stage constant current charging, second stage floating charge cycle, the third stage floating;

2 with reverse battery protection, overcharge protection, short circuit protection, charging voltage and battery temperature compensation without prompt functions;

The 2 charging module can use parallel redundant, can provide 60A charging current;

3) monitoring module: module configuration 5.7 inch touch screen, UPS display at a glance, save the key operation cumbersome, convenient maintenance. The monitoring module can easily check the working state of UPS, the real-time parameters of the input and output of the charger and the battery status, and can store 3700 historical records.

 

 监控模块4

4: EA660) cabinet cabinet from the power distribution unit, lightning protection unit, communication interface, connecting terminal;

The power distribution unit: input and output, maintenance bypass switch; 200KVA system (20KVA module) and 250KVA system (25KVA module) with power distribution unit.

Lightning protection unit: the C level of lightning protection module;

Communication interface: Standard RS232, USB, RS485, dry contact; optional SNMP card;

 

5) battery: all modules share battery pack

The input circuit architecture and advanced control strategy of dual battery used, and machine system share the same battery, compared to not total battery and system, greatly reduced the cost of the battery.

 

4.2, EA660 Series modular the main features of UPS

2 ultra wide input voltage and frequency.

The input voltage range is 204Vac ~ 520Vac, 277Vac ~ (a) 520Vac (full), suitable for large city power grid fluctuations, reduce the battery discharge times, thereby prolonging the service life of the battery;

The input frequency range is 40 ~ 70Hz, meet all kinds of generator equipment;

2 Super Widescreen LCD touch

The 5.7 inch touch screen LCD menu design and architecture, all kinds of information can be monitored by UPS LCD, all operations at a glance.

2 modular design

Modular design, module capacity of 20KVA/25KVA, UPS from 1 to 10 UPS modules, 1 to 2 charging module, 1 monitoring module, the user can increase the number of UPS modules and flexibility according to the load gradually put into. Each module and a cabinet with "hot swap" technology, all online modules can be hot swappable, zero maintenance time.

2 decentralized bypass control

Each power module has independent bypass function, avoid single point bottleneck bypass appeared;

2 flexible system configuration

Our company has 80KVA, 100KVA, 160KVA, 200KVA, 250KVA system, users can flexibly configure; for the future expansion of equipment, as long as the user first installed, will switch left margin and cable, when the load increases again as long as the purchase of UPS module can be UPS capacity expansion, completely avoid the traditional UPS for the first time the shortcomings of the large equipment investment, truly "edge edge growth investment, saving valuable funds for users.

2 flexible parameter setting and configuration of battery charging

The user can according to the demand, through the LCD screen set battery number, battery number, battery capacity, charging rate and temperature compensation coefficient and other key parameters of charging. The number of battery battery group can within section 16/17/18/19/20 of arbitrary configuration, note: the battery must be.

2 intelligent battery management

Independent intelligent charging module, automatic battery three stage intelligent charging management. The first stage constant current charging, fast charging back to about 90% of the electricity; second phase high voltage charging circuit, the battery voltage can homogenize and charge the battery completely; third stage floating maintenance, ensure no loss of power. At the same time, the charging module also batteryreverse protection, overcharge protection, short circuit protection, battery charging and missed prompt voltage temperature compensation function;

2 standard input, output, maintenance bypass switch

Standard input, output, maintenance bypass switch, convenient installation and operation, while reducing the user cost, purchasing power distribution cabinet area;

2 standard C lightning protection module

With lightning surge protection function, effectively prevent equipment damage caused by lightning;

2 Super protective treatment

The air inlet machine design with dustproof net imports, the internal PCB board adopts three processing, moisture-proof, anti mildew, smoke, to ensure it is applicable to a variety of harsh environment;

2 rich communication interface function

The standard USB, RS232, RS485, SNMP, matching the dry contact card, to meet user communication requirements.

 

4.3, EA660 series of modular UPS Technology

A high reliability design technology

1、 The power module adopts an independent control system, improve the reliability of the system

The module has a complete set of UPS functions, rectifier, inverter and control in one, without external synchronization control signals or other means of control, the module can work normally, single point bottleneck exists to reduce the system operation and control, improve the reliability of the whole machine.

 5

2、 UseN+XRedundant parallel technology, improve the reliability of the system

UPSThe reliability of single redundant MTBF = increase

EA660 series of modular UPS system uses N+X modular redundancy and machine technology, eliminate single points of failure bottlenecks in the system, UPS system is currently the main way to improve the reliability; at the same time customers can choose more than one to more than two module redundancy, redundancy design full load operation security;

The modular structure of the electrical system diagram, can be seen from the figure, the power module using the N+X redundancy:

 

 6

The traditional single machine, N+1Redundant machine, modular UPSThe reliability comparison:

 

 

The traditional single machine

N+1 redundancy and machine

modular UPS

Work characteristics

UPS system failure, customers must switch to bypass or even shut down for maintenance;

The UPS system only one fault rate, where a UPS appointment after the failure, the customer must promptly rushed to the scene for troubleshooting; in addition, the number of single parallel UPS increase, and will cause the machine line and increase circulation, and reduce the system reliability;

Using N+X architecture, the client can choose more than one to more than two module redundancy, redundancy design comprehensive protection load operation; in addition, all power modules in a cabinet system, without any additional and machine line;

Redundancy

nothing

1 times

X

reliability

low

in

high

Technical advantage two, green environmental protection, high efficiency and energy saving

 

1Green environmental protection, reduce procurement costs

 

The EA660 series uses IGBT average current control technology, the load changes from 10%-100%, the PF is greater than 0.99, THDI less than 3%, no interference on the power grid, is truly green power.

The topology as shown below:

 7

The traditional SCR6 pulse rectifier IGBT rectifier waveform waveform of traditional SCR12 pulse rectifier waveform

The input harmonic current, harmonic current of 3% input: < > > 10%: 30% input harmonic current

The input power factor: 0.99 input power factor: 0.85 input power factor: 0.90

 

The input power due to the use of higher cost, the smaller the input harmonic current can greatly save users, mainly in the following aspects:

1, reduce the front end of the UPS power transformer and generator capacity ratio, improve the utilization rate of power generation and transmission equipment;

2, reduce the input ratio of the cable specifications and switching capacity;

3, reduce the power loss and power transmission equipment;

4, reduce the harmonic current caused by electrical equipment malfunction.

For example:

Calculated in accordance with the configuration of UPS capacity 100KVA:

EAST EA66100 (100KVA) the ratio of generator capacity is 1.2:1, 1.2 * 100KVA=120KVA

Domestic generators ratio capacity of some brand 100KVA 3:1, 3 * 100KVA=300KVA

Therefore, EAST products only need 120KVA generator at home and abroad, some brands need to configure a 300KVA generator, thus increasing the cost of the user 180KVA generator.

 8

 

2High efficiency and energy saving, reduce operating costs

 

EA660 series UPS uses three level vector modulation technology, reduces the switching losses within the device, so as to enhance the efficiency of the whole machine, the work efficiency is more than 93%.

The efficiency is high, the user cost is lower; on the contrary, the lower the efficiency, will increase operating costs;

 9

For example:

EAST EA660 series machine efficiency is 93%, some domestic and foreign brand power machine efficiency is 88% (loss, SCR rectifier input loss, harmonic filter control method reduces the overall efficiency)

Taking 100KVA UPS as an example, according to each UPS runs 24 hours a day, electricity 1.5 yuan / kWh calculation, the efficiency was 88% UPS per year to pay electricity: 0.05*100000*0.8*24*365*1.5=5.2 million;

Therefore, if the use of our EA660 series UPS, every year can save 52 thousand yuan electricity;

 

Technical advantage three, flexible configuration, on-demand expansion, dynamic growth;

EA660 UPS for the whole series of modular design, the system capacity can be extended from 20KVA to 250KVA, the design concept of power module is running in the system can easily be removed and installed, without affecting the operation and output of the system;

If the user in accordance with the pre modular UPS maximum system capacity configuration of switch and cable, when the load increase later, only need to buy the power module, the UPS can be expanded to the power required, completely avoid the traditional UPS for the first time, the shortcomings of the large equipment investment, make the investment plan to achieve "on-demand expansion". Let the user with business development to achieve "dynamic growth", not only meet the demand expanded equipment, but also reduce the initial purchase cost.

In general, the user is expected in UPS capacity, often appear to underestimate or high expected conditions, EA660 Series modular UPS can effectively solve the above problem, construction and investment stages to help users in the future development direction is not clear case. When the user load increases, only need to increase the planning stage of the power module.

 10

For example:

A room, the load is 60KVA, 1 years after the load capacity of up to 80KVA; 2 years after the load capacity of up to 120KVA; 3 years after the load capacity of up to 160KVA, the subsequent increase in load capacity.

The traditional UPS has two kinds of configuration:

1, according to the customer's actual load configuration UPS, the results are as follows: 60KVA1; 20KVA1; 40KVA1; 40KVA1 Taiwan, a total of 4 sets of UPS configuration, and each configuration of the UPS need UPS placement, and the configuration and installation of input and output cable, the UPS and the installation cost is much higher than buy a the cost of 160KVA.

2, according to the following maximum load capacity configuration UPS, therefore, need to configure a 160KVA UPS, but due to the current load power is 60KVA, the load rate is 37%, the efficiency was 78%, with 88% full load efficiency is 10%,A year of electricity costs increased by about 63 thousandIn addition, UPS will also cost a year of sluggish 100KVA.

 

 

Modular configuration design of UPS:

According to the following maximum load capacity, the configuration of a 160KVA system cabinet, 4 20KVA power module (1 redundant backup) 60KVA+1 configuration cost, improve the efficiency and save the cost of procurement early, with the subsequent load power increases, the direct purchase of power module, without increasing the area and installation;

 

Technical advantage four, easy maintenance and intelligent management design

1MTTR(The mean time to repair)Close to0

 

The traditional UPS system are taken to bypass work in daily maintenance, equipment maintenance period, so the load not protected by UPS, at this time if the AC power interruption and overload fault, will cause the load power supply interruption or equipment damage. At the same time, equipment maintenance also need to go through a series of cumbersome procedures: the system administrator to notify the manufacturer - manufacturers rushed to the site maintenance: maintenance outage. The traditional UPS maintenance time in more than 2 hours, or even more than 1 days.

In order to solve the traditional UPS which exists in the maintenance problems, EA660 UPS uses a series of advanced technology of hot swap module,Charging module and system monitoring module, power moduleHot plug can be online, without power cut operation. The online parallel system maintenance, at the same time the operation without special instruments and techniques can be carried out, the general maintenance time will be able to solve the problem in 1 minutes.

EA660 series UPS through the hot swap technology makes the single power module can be any online input or exit, to overcome the traditional UPS to bypass maintenance technical problems, make the maintenance convenient at the same time achieve the UPS abnormal, free expansion and redundant two performance, fully meet the actual needs of users.

 

2In English, large screen display, can display the parameters of input and output, batteries, rectifier, bypass, and the work of the whole state, historical records, battery management and other functions, to facilitate maintenance personnel maintenance operation;

 11






3Intelligent monitoring and management

The monitoring module, USB, RS485, RS232 and other dry contact communication interface monitoring the operation state of UPS. With remote SNMP network management (optional) function, support TCP/IP protocol to realize remote network management. UPS SMS alarm management platform, send text messages to mobile phone through GSM network can alarm the administrator. Support networking scheme is flexible, convenient everywhere, monitoring and management of UPS.

 12

13




4.4, EA660 Series modular technical parameters UPS

 

Model

 

250KVA (maximum expansion to 250KVA)

 

input

 

Rated input voltage

380Vac

The load is less than or equal to 50%

204~520Vac

50% < < 70% load

242~520Vac

70% < < 100% load

277~520Vac

Input mode

Three-phase five wire

The input power factor

≥0.99

The total harmonic distortion (THDI)

≤3%

Rated frequency

Adaptive 50Hz/60Hz

frequency range

40~70Hz

Bypass voltage range

380Vac + 20% (set)

output

 

output power

 

60KVA (3 20KVA module)

 

 

Rated voltage

380Vac

Steady state voltage accuracy

±1%

Transient voltage variation range

+ 5% (0 ~ 100% load changes)

The total harmonic distortion (THDV)

= 1% (resistive load) = 4% (nonlinear load);

The output voltage of the DC component

≤100mv

The output voltage peak coefficient

3:01

output frequency

Power mode: synchronization and power; battery mode: 50Hz/60Hz

Frequency tracking rate

≤1Hz/s

The precision of PLL

1 degrees (power frequency 45 ~ 55Hz, steady state)

Inverter overload capacity

110% < < 130% load, 10 minutes after the bypass; 130% < load is less than 150%, 1 minutes after the turn bypass; load > 150%, 0.5s bypass

Bypass overload capacity

150%, long time operation; more than 150%, for 10s

Electric mode vs. battery mode

0ms

Bypass mode vs. power mode

0ms

system

 

The working efficiency of the whole machine

≥94%

Cell number

Section 12V40 (support 32,34,36,38)

The maximum charge current

60A

The number of parallel modules

 

From 1 to 10

 

The number of redundant modules

 

From 0 to 9

 

Working temperature range

0~40℃

High altitude

< 1500m (beyond the height reduction of use)

Relative humidity

0-95%

Storage temperature

 -25℃~55℃

Distance of 1 meters from the surface noise

<60dB

security

EN62040-1-1

Electrostatic discharge

IEC61000-4-2 Level3

Continuous electromagnetic sensitivity

IEC61000-4-3 Level3

Voltage flash compatibility

IEC61000-4-4 Level3

Surge interference

IEC61000-4-5 Level4

Electromagnetic interference (EMI)

EN62040-2(>25A)classA

The UPS cabinet size

(w * D * h)

 

600mm×1000mm×2000mm

UPS module size

(w * D * h)

482mm×590mm×131mm

The weight of the UPS cabinet

 

288kg

 

Weight UPS

28KG (single UPS module)

colour

black

Control panel

5.7 inch Widescreen LCD touch function

Sound alarm

Battery mode alarm alarm, battery power is very low, fan fault alarm etc.

Interface

USB, RS232, RS485, dry contact (standard)

Option

SNMP card

The built-in power distribution unit

 

yes

 

               

 

 