Our 380V10KVA Reddy external battery UPS power three single host 8KWG31-10KL

price:USD$8500.00
discount 70% in 2018-10-24 to 2018-10-26
price: USD$ 5950.00
freight :USD$18.00,(Express)
freight :USD$7.00,(Postal parcel)
views:0
Search Similar or mail to saler or send message to saler

Pay with PayPal, PayPal Credit or any major credit card

Product selection navigation table
Navigation table for power supply and time configuration of UPS,blueText Click to connect to the corresponding commodity, the corresponding power equipment needs to delay the configuration of the time
The calculation method of UPS (the number of standby time: X12V battery voltage single battery capacity X battery / power equipment) X0.7 = loss can prolong the time (hours): G1KL configuration 3 100AH battery for the use of 600W equipment for (100AHX3X12V) /600WX0.7=4.2H (hours)
brandpowerModelUnit PriceVoltage regulator (input range)Applicable equipmentLCD screenAutomatic switch machineSpare time (minutes)
Reddy company360WD600188 yuanRegulated 145-290V1 computers///////////1 PC = 20
Reddy company500WD1000M278 yuanRegulated 145-290V2 computers///////////1 PC = 30,2 PC = 10
Reddy company600WD1000350 yuanRegulated 145-290V3 computers///////////1 PC = 45,2 = 25,3 = 12 Taiwan Taiwan
Reddy company1800WD30001180 yuanRegulated 145-290V12 computersYesAutomatic switch machine1 PC = 120,2 = 60,3 = 40 Taiwan Taiwan
Reddy company360WH600218 yuanRegulated 145-290V1 computersYesAuto Power On1 PC = 20
Reddy company500WH1000M298 yuanRegulated 165-276V2 computersYesAuto Power On1 PC = 30,2 PC = 10
Reddy company600WH1000398 yuanRegulated 165-276V3 computersYesAutomatic switch machine1 PC = 45,2 = 25,3 = 12 Taiwan Taiwan
Reddy company900WH1500590 yuanRegulated 165-276V4 computersYesAutomatic switch machine1 PC = 60,2 = 30,3 = 15 Taiwan Taiwan
Reddy company1200WH2000780 yuanRegulated 165-276V6 computersYesAutomatic switch machine1 PC = 60,3 = 15,6 = 5 Taiwan Taiwan
The use of engine power after the power outage time \ \ \ \10 minutes30 Minutes1 hours2 hours4 hours8 hours
1KVA/600WUPS host H1000L398 yuan990 yuan1090 yuan1260 yuan2550 yuan3800 yuan
2KVA/1200WUPS host H2000L780 yuan1550 yuan2080 yuan3400 yuan4600 yuan8300 yuan
Online 1KVA/800WUPS host G1KL1160 yuan1800 yuan2150 yuan2480 yuan2930 yuan4800 yuan
Online 2KVA/1600WUPS host G2KL2100 yuan3390 yuan3900 yuan4900 yuan5600 yuan9250 yuan
Online 3KVA/2400WUPS host G3KL2300 yuan4110 yuan5200 yuan6200 yuan7180 yuan12000 yuan
Online 6KVA/4800WUPS host G6KL5200 yuan7800 yuan9500 yuan12000 yuan14200 yuan25200 yuan
Online 10KVA/8000W host G10KL8200 yuan11800 yuan14800 yuan16800 yuan27600 yuan49500 yuan
It 10KVA/8KWG31-10KL9500 yuan13200 yuan16200 yuan18200 yuan29000 yuan50900 yuan
It 15KVA/12KWG31-15KL16800 yuan19600 yuan21500 yuan35600 yuan51300 yuan79200 yuan
It 20KVA/16KWG31-20KL19890 yuan23500 yuan28200 yuan40800 yuan59400 yuan103000 yuan
It 30KVA/24KWG31-30KLThree three 10KVA/8KW host G33-10KLThree three 20KVA/16KW host G33-20KL
Three three 30KVA/24KWG33-30KLThree three 40KVA/32KW host G33-40KLThree three 60KVA/48KW host G33-60KL
Rack type tower dual exchange GR1KL1KVA/800W host1500 yuan (standard machine with battery pack)Rack type tower dual exchange GR6KL6KVA/4800W host6680 yuan (standard machine with battery pack)
Rack type tower dual exchange GR2KL2KVA/1600W host2980 yuan (standard machine with battery pack)Rack type tower dual exchange GR10KL10KVA/8000W host8800 yuan (standard machine with battery pack)
Rack type tower dual exchange GR3KL3KVA/2400W host3600 yuan (standard machine with battery pack)
G31series10K/15K/20K VA 
Product features
Real implementation of online dual conversion
High performance machine using DSP Technology
The output power factor is 0.8
The output frequency can be selectively adjusted to 50Hz/60Hz
Emergency power off (EPO)
ECO mode provides energy saving effect (ECO)
Wide power input range (110-300VAC)
The built-in phase adaptive function, three single or single inlet and outlet can be adjusted
Note: add (LRepresents a long delay hostG31-10KBuilt in battery for standard machine,G31-10KLFor long acting machine plus battery; addISOThe output voltage is optional
Product specification
type of machineG31-10K(L)G31-10K(L) ISO G31-15K(L)G31--20K(L)G31-20KL ISO 
phaseThree single
capacity10000VA/8000W10000VA/8000W15000VA/12000W20000VA/16000W20000VA/16000W
input
Voltage rangeLow voltage switching176VAC (in-phase voltage) + 3%@100% load; 110VAC (in-phase voltage) + 3%@50% load
Low voltage recovery186VAC (in-phase voltage) + 3%@100% load; 120VAC (in-phase voltage) + 3%@50% load
High voltage switching300VAC (in-phase voltage) + 3%
High voltage recovery290VAC (in-phase voltage) + 3%
frequency range46~54Hz or 56~64Hz
power factorThe load is greater than or equal to 0.99@100%
output
output voltage208/220/230/240VAC104/110/115/120VACor208/220/230/240VAC208/220/230/240VAC104/110/115/120VACor208/220/230/240VAC
Voltage range (battery mode)± 1 %
Frequency range (synchronous correction range)46~54Hz or 56~64Hz
Frequency range (battery mode)50Hz + 0.1Hz or 60Hz + 0.1Hz
Surge ratio03:01
Harmonic distortion2%THD (linear load); 5%THD (nonlinear load)2%THD (linear load); 6%THD (nonlinear load)2%THD (linear load); 5%THD (nonlinear load)2THD (linear load); 5%THD (nonlinear load)2%THD (linear load); 7%THD (nonlinear load)
Conversion timeAC to DC0
Invert to bypass0
Waveform (battery mode)Pure sine wave
efficiency
Electricity mode89.00%85.00%89.00%89.00%87.00%
Battery mode86.00%83.00%88.00%87.00%83.00%
Battery
Standard machineBattery type12V / 9AhNo
Number20pcs (18-20 adjustable) *20pcs (18-20 adjustable) *
Standard charging time9 hours charge to 90%
Maximum charging current1.0 A2.0 A
Charging voltage273.0 VDC ±1%
Long acting machineBattery quantity12V / 16only
Maximum charging current4.0 A4.0 A8.0 A
Charging voltage218.4 VDC ±1%
Display specification
LCD or LEDLoad size, battery capacity, power mode, battery mode, bypass mode, fault indication
warning sound
Battery modeIt sounds every 4 seconds
Low batteryOne second per second
overloadIt sounds every 0.5 seconds
errorContinuous ringing
physical property
standard levelSize, depth x, width x high (mm)592 x 250 x 576592 X 250 X 826815 X 250 X 826No
Net weight (kgs)83144164164
Long-acting aircraftSize, depth x, width x high (mm)592 X 250 X 576592 X 250 X 826592 X 250 X 576592 X 250 X 576815X 250 X 826
Net weight (kgs)28914040144
Using environment
humidity0-95%RH@0-40 degree C (without condensation)
noiseLess than 55dBA@1 metersLess than 60dBA@1 meters
Control management
Smart RS-232/ optional USBSupport Windows2000/2003/XP/Vista/2008/7/8, Linux, Unix, andMAC
Optional SNMPPower management supports SNMP management and network management
When the UPS is a constant voltage constant frequency mode, the output power will decrease by 40%. When the output voltage of the UPS is set to 208VAC, the output power will decrease by 10%.
* when the internal battery number is changed to 16-19, the machine will output in accordance with the following formula: P=PRatingX (N/20x100%)
If the machine is installed at a height of 1000 meters above sea level, the power output will decrease by 1% per 100m rise
The current product specifications are subject to change without further notice